Issue:
% Flow Record: Failed to field add: Failed to validate Unsetting Public:behaviour
% Flow Monitor: Failed to add monitor to interface: Unsupported key field "interface input" for ip traffic in Output direction

To avoid that use separate monitors for inbound and outbound monitors.


!
flow record FR-INPUT
 match ipv4 tos
 match ipv4 protocol
 match ipv4 source address
 match ipv4 destination address
 match transport source-port
 match transport destination-port
 match flow direction
 match interface input
 collect counter bytes long
 collect counter packets long
!
!
flow record FR-OUTPUT
 match ipv4 tos
 match ipv4 protocol
 match ipv4 source address
 match ipv4 destination address
 match transport source-port
 match transport destination-port
 match flow direction
 match interface output
 collect counter bytes long
 collect counter packets long
!
!
flow exporter EXPORT1
 destination 10.74.12.38
 source Vlan170
 transport udp 2055
!
!
flow monitor MONITOR-INPUT
 exporter EXPORT1
 cache timeout active 300
 record FR-INPUT
!
!
flow monitor MONITOR-OUTPUT
 exporter EXPORT1
 cache timeout active 300
 record FR-OUTPUT
!



vlan configuration 1,31,40,170,184,193-207,242
ip flow monitor MONITOR-INPUT input
ip flow monitor MONITOR-OUTPUT output
!

4 комментария:

  1. Ngoài dịch vụ vận chuyển hàng hóa bằng đường sắt, Ratraco Solutions còn cung tới quý khach hàng dịch vụ đóng gói, bốc xếp hàng hóa nhanh chóng, giá rẻ. Liên hệ 0965 131 131 để biết cụ thể dịch vụ của chúng tôi.

    ОтветитьУдалить
  2. Привет друг, отчаялся тебя искать уже, скажи пожалуйста что в итоге было с твоей авео при 2800-3000 оборотах? И удалось ли исправить?

    ОтветитьУдалить
    Ответы
    1. сгонял к салон, описал симптомы. Вернули тачку через пол часа. Сказали, что не подтвердился диагноз. Обороты больше не гуляли. Вот такая история.

      Удалить
  3. Напиши мне сюда если увидишь - solution.n@bk.ru

    ОтветитьУдалить